SESSION LIBRARY
Old Sessions
Browse recordings stored in this browser, check EEG and video quality, and open any session in Review. Quality uses the same raw EEG window rules as Review; display interpolation is never used.
Loading local sessions…
No sessions selected.
RECORDING HISTORY
Recorded sessions
QUALITY METRICS
How to read this page
Cognitive EEG uses the exact Review QC on raw acquired samples: 5 s windows, 1 s hop, Amp + RMS + 1/f (−4 to −0.2 exploratory) + gaps. A window is accepted when at least one available ear passes the four checks. Behavior EEG uses 1.5 s windows, 0.5 s hop, and gap/coverage checks only (no amplitude, RMS or 1/f rejection). Video reports the percentage of MediaPipe-analyzed frames containing a face, when saved. Sync is evaluated separately and should be checked before model training. A percentage of overlapping windows is not a percentage of independent trials. Cached QC can be refreshed with “Recalculate QC”.
Sessions are held in this browser (IndexedDB), not in a regular Windows folder. Use Archive ZIP to back up an individual session, or Choose archive folder in supported Chrome/Edge browsers to save ZIP files directly to a folder you select. Otherwise the ZIP goes to Downloads. Keep a separate backup before deleting any recording. Import ZIP restores a portable session. Dataset selection and preview are available in v0.7.50; session-held-out Behavior and Cognitive EEG training is available in Model.
DeepWave